============ MuSR Changes ============ .. contents:: Table of Contents :local: New ### - New fitting functions added and muon fitting functions re-organised into MuonGeneric, MuonSpecific and MuonModelling. - Newly added functions are: - MuonGeneric - :ref:`CombGaussLorenzKT` - :ref:`StaticLorentzianKT ` - :ref:`StretchedKT ` - :ref:`StandardSC ` - MuonModelling - :ref:`Redfield ` - MuonSpecific - :ref:`AFMLF ` - :ref:`AFMZF ` - :ref:`Bessel ` - :ref:`CompositePCRmagnet ` - :ref:`DampedBessel ` - :ref:`FmuF ` - :ref:`GauBroadGauKT ` - :ref:`GaussBessel ` - :ref:`HighTFMuonium ` - :ref:`LowTFMuonium ` - :ref:`Meier ` - :ref:`ModOsc ` - :ref:`MuMinusExpTF ` - :ref:`MuH ` - :ref:`PCRmagRedfield ` - :ref:`PCRmagnetZFKT ` - :ref:`PCRmagnet ` - :ref:`PCRmagnetfnorm ` - :ref:`RFresonance ` - :ref:`SpinGlass ` - :ref:`TFMuonium ` - :ref:`ZFdipole ` - :ref:`ZFelectronDipole ` - :ref:`ZFMuonium ` - :ref:`ZFprotonDipole ` Improvements ############ - The speed of plotting during Sequential Fits. - Removed the creation of a group of groups from the Elemental Analysis GUI. It will now create a workspace for each detector, with each workspace containing three spectra corresponding to Total, Delayed and Prompt data. - Muon Analysis Interface>Fitting>Property>TF Asymmetry mode now rescales the fit to match the rescaled data. - Adding a pair by right clicking now allows a name to be specified. - The ALC interface can now safely be closed while loading a set of runs. On an initial close request the algoirthm will be cancelled. The window then be closed. Algorithms ------------- - Improve the handling of :ref:`LoadPSIMuonBin` where a poor date is provided. - :ref:`LoadPSIMuonBin ` has been improved to correctly load data other than data from Dolly at the SmuS/PSI. - When there is a T0 for each spectrum, :ref:`LoadPSIMuonBin ` chooses the max value out of the array instead of the first value. .. figure:: ../../images/MuonAnalysis.PNG :class: screenshot :width: 600px :align: right Muon Analysis 2 and Frequency Domain Interfaces --------------------------------------------------- - When loading PSI data if the groups given are poorly stored in the file, it should now produce unique names in the grouping tab for groups. - When switching between Data Sets, Groups selected to fit are remembered. - The Frequency Domain>Transform>FFT tab now uses Group Pair Selection to guess at the User's selection for workspaces. - Can now plot FFT's of PhaseQuad data. - Both interfaces work with Project Recovery. - The original Muon Analysis GUI has been renamed "Muon Analysis Old" and has been deprecated. - \* **The new Muon Analysis GUI has been renamed Muon Analysis.** \* Bug Fixes ######### - No longer produces an error if using multiple runs and the user plots all the FFT results when no imaginary data was used. - Fixed an issue where changing the normalisation on a plot with auto-scale disabled throws an exception. - Fixed an issue where warnings about adding workspaces to workspace groups multiple times were appearing in the log. - Fixed an issue where logs in TF asymmetry mode were not being propogated to the results tab. - Fixed an issue where Muon Analysis 2 would crash if a polynomial background was used in combination with another fitting function. - Fixed an issue where changing the dead time to from table workspace or other file did not work and reverted back to from data file. - Fixed an issue where the Auto button in the ALC interface would crash mantid if it failed to find a list of valid of files. It will now show an error if it fails to find a set of files. \* **See associated Image** \* :ref:`Release 4.2.0 `