IndirectAnnulusAbsorption v1

../_images/IndirectAnnulusAbsorption-v1_dlg.png

IndirectAnnulusAbsorption dialog.

Summary

Calculates indirect absorption corrections for an annulus sample shape.

Properties

Name Direction Type Default Description
SampleWorkspace Input MatrixWorkspace Mandatory Sample workspace.
SampleChemicalFormula Input string Mandatory Chemical formula for the sample
SampleNumberDensity Input number 0.1 Sample number density
SampleInnerRadius Input number 0.2 Sample radius
SampleOuterRadius Input number 0.25 Sample radius
CanWorkspace Input MatrixWorkspace   Container workspace.
UseCanCorrections Input boolean False Use can corrections in subtraction
CanChemicalFormula Input string   Chemical formula for the can
CanNumberDensity Input number 0.1 Can number density
CanInnerRadius Input number 0.19 Sample radius
CanOuterRadius Input number 0.26 Sample radius
CanScaleFactor Input number 1 Scale factor to multiply can data
Events Input number 5000 Number of neutron events
Plot Input boolean False Plot options
OutputWorkspace Output MatrixWorkspace Mandatory The output corrected workspace.
CorrectionsWorkspace Output WorkspaceGroup   The corrections workspace for scattering and absorptions in sample.

Description

Calculates and applies corrections for scattering abs absorption in a annular sample for a run on an indirect inelastic instrument, optionally allowing for the subtraction or corrections of the container.

The correction factor workspace is a workspace group containing the correction factors in the Paalman and Pings format, note that only {A_{s,s}} and A_{c,c} factors are calculated by thsi algorithm.

Usage

Note

To run these usage examples please first download the usage data, and add these to your path. In MantidPlot this is done using Manage User Directories.

Example - Sample corrections for IRIS:

red_ws = LoadNexusProcessed(Filename='irs26176_graphite002_red.nxs')
can_ws = LoadNexusProcessed(Filename='irs26173_graphite002_red.nxs')

corrected, fact = IndirectAnnulusAbsorption(SampleWorkspace=red_ws,
                                            SampleChemicalFormula='H2-O',
                                            CanWorkspace=can_ws,
                                            CanScaleFactor=0.8,
                                            CanInnerRadius=0.19,
                                            SampleInnerRadius=0.2,
                                            SampleOuterRadius=0.25,
                                            CanOuterRadius=0.26,
                                            Events=200)

ass = fact[0]

print ('Corrected workspace is intensity against %s'
      % (corrected.getAxis(0).getUnit().caption()))

print ('Ass workspace is %s against %s'
      % (ass.YUnitLabel(), ass.getAxis(0).getUnit().caption()))

Output:

Corrected workspace is intensity against Energy transfer
Ass workspace is Attenuation factor against Wavelength

Example - Sample corrections for IRIS:

red_ws = LoadNexusProcessed(Filename='irs26176_graphite002_red.nxs')
can_ws = LoadNexusProcessed(Filename='irs26173_graphite002_red.nxs')

corrected, fact = IndirectAnnulusAbsorption(SampleWorkspace=red_ws,
                                            SampleChemicalFormula='H2-O',
                                            CanWorkspace=can_ws,
                                            CanChemicalFormula='H2-O',
                                            CanInnerRadius=0.19,
                                            SampleInnerRadius=0.2,
                                            SampleOuterRadius=0.25,
                                            CanOuterRadius=0.26,
                                            Events=200,
                                            UseCanCorrections=True)

ass = fact[0]
acc = fact[1]

print ('Corrected workspace is intensity against %s'
      % (corrected.getAxis(0).getUnit().caption()))

print ('Ass workspace is %s against %s'
      % (ass.YUnitLabel(), ass.getAxis(0).getUnit().caption()))

print ('Acc workspace is %s against %s'
      % (acc.YUnitLabel(), acc.getAxis(0).getUnit().caption()))

Output:

Corrected workspace is intensity against Energy transfer
Ass workspace is Attenuation factor against Wavelength
Acc workspace is Attenuation factor against Wavelength

Categories: Algorithms | Workflow\Inelastic | CorrectionFunctions\AbsorptionCorrections | Workflow\MIDAS