Home Tab

../_images/frequency_domain_analysis_2_home.png

Pre-processing parameters

Instrument This selects the instrument used by the GUI

Time Zero This is the time zero value used. By default the time zero is taken from the file but it can be specified here in which case the specified time zero is used for all calculations.

First Good Data This is the first good data value used. By default the time zero is taken from the file but it can be specified here in which case the specified first good data is used for all calculations.

Deadtime The default is to use no deadtime correction. There are three deadtime correction options if required.

  • From data file: The deadtime table will be taken from the relevant data file
  • From table workspace: A previously loaded deadtime table may be selected which will then be used in all group and pair calculations.
  • From other file: A file may be selected to load a deadtime table from this will then be used in all group and pair calculations.

Rebin

Fixed Fixed rebinning allows a scale factor to be entered which will then be used to scale the raw bins.

Variable Variable binning allows a string to be entered which specifies the required binning. The string is of the format used by the Rebin algorithm.

Groups and Pairs

Periods For multi period data the Summed and Subracted periods may be specified here. These periods will then be used for all groups and pairs.