PCRmagnetfnorm

Description

ZF signal from PCR ordered magnet with normalised relaxation rate

A(t)=A_0\left(\frac{1}{3}+\frac{2}{3}e^{-(\sigma_\omega\omega t')^2/2}\cos(\omega t)\right)

where,

\omega=g_\mu H_0 ,

t'=t-t_\text{off} ,

A_0 is the amplitude,

\sigma_\omega (MHz) is the normalised relaxation rate,

H0 (G) is the local magnetic field,

g_\mu is the gyromagnetic ratio of muons,

and t_\text{off} (microsecs) is the time offset.

(Source code, png, hires.png, pdf)

../../_images/PCRmagnetfnorm-1.png

Properties (fitting parameters)

Name Default Description
A0 0.2 Amplitude
SigmaOverW 0.1 Normalised relaxation rate
H0 3.0 Local magnetic field
Toff 0.1 Time offset

Source

Python: PCRmagnetfnorm.py (last modified: 2019-11-14)