\renewcommand\AA{\unicode{x212B}}
A relatxation function for negative muons in Traverse field.
where,
N_O is the count at t=0 ,
\tau is the muon decay life time,
A is the relative amplitude of the oscillatory term,
\lambda (MHz) is the relaxation rateo f the oscillatory term,
\nu is the oscillating frequency,
and \phi is the phase.
(Source code, png, hires.png, pdf)
Name | Default | Description |
---|---|---|
A | 1.0 | |
Lambda | 0.1 | Decay rate of oscillating term |
N0 | 1.0 | |
Tau | 5.0 | |
Phi | 0.3 | Phase |
Nu | 0.2 | Oscillating frequency (MHz) |
Python: MuMinusExpTF.py (last modified: 2020-03-20)