\(\renewcommand\AA{\unicode{x212B}}\)
Table of Contents
Name | Direction | Type | Default | Description |
---|---|---|---|---|
InputFiles | Input | str list | Comma separated list of input files | |
LoadLogFiles | Input | boolean | True | Load log files when loading runs |
CalibrationWorkspace | Input | Workspace | Workspace containing calibration data | |
Instrument | Input | string | Mandatory | Instrument used during run. Allowed values: [‘IRIS’, ‘OSIRIS’] |
Analyser | Input | string | Mandatory | Analyser bank used during run. Allowed values: [‘graphite’, ‘mica’, ‘fmica’] |
Reflection | Input | string | Mandatory | Reflection number for instrument setup during run. Allowed values: [‘002’, ‘004’, ‘006’] |
SpectraRange | Input | long list | 0,1 | Comma separated range of spectra number to use. |
ElasticRange | Input | dbl list | Energy range for the elastic component. | |
InelasticRange | Input | dbl list | Energy range for the inelastic component. | |
TotalRange | Input | dbl list | Energy range for the total energy component. | |
DetailedBalance | Input | number | Optional | Apply the detailed balance correction |
GroupingMethod | Input | string | Individual | Method used to group spectra. Allowed values: [‘Individual’, ‘All’, ‘File’, ‘Workspace’, ‘IPF’] |
GroupingWorkspace | Input | Workspace | Workspace containing spectra grouping. | |
MapFile | Input | string | File containing spectra grouping. Allowed extensions: [‘.map’] | |
SampleEnvironmentLogName | Input | string | sample | Name of the sample environment log entry |
SampleEnvironmentLogValue | Input | string | last_value | Value selection of the sample environment log entry. Allowed values: [‘last_value’, ‘average’] |
MSDFit | Input | boolean | False | Perform an MSDFit |
SumFiles | Input | boolean | False | Toggle input file summing or sequential processing |
ReducedWorkspace | Input | string | Reduced | Workspace group for the resulting workspaces. |
ScanWorkspace | Input | string | Scan | Workspace for the scan results. |
Performs a data reduction from ISISIndirectEnergyTransfer, before performing the ElasticWindowMultiple algorithm over the elastic and inelastic regions of the reduced data to calculate the elastic incoherent scattering factor. There is also an option to perform the MSDFit algorithm.
Note
To run these usage examples please first download the usage data, and add these to your path. In Mantid this is done using Manage User Directories.
Example - IRIS Energy Window Scan
EnergyWindowScan(InputFiles="IRS21360.RAW", Instrument='IRIS', Analyser='graphite',
Reflection='002', SpectraRange='3, 50', ElasticRange='-0.5, 0',
InelasticRange='0, 0.5', GroupingMethod='Individual', MSDFit=True)
Categories: AlgorithmIndex | Workflow\Inelastic | Inelastic\Indirect | Workflow\MIDAS
Python: EnergyWindowScan.py (last modified: 2020-03-20)