\(\renewcommand\AA{\unicode{x212B}}\)
Direct Inelastic Changes
- Data reduction workflow algorithms for ILL’s TOF spectrometers IN4, IN5 and IN6 have been added to Mantid. A guide to the six new algorithms is provided here.
- The detector efficiency correction formulas for ILL’s IN4, IN5 and IN6 spectrometers have been revised. IN4 has now separate formulas for the low and large angle detectors while the previously incorrect IN5 and IN6 formulas were fixed.
- New \(T_0\) formula for CNCS instrument
- Added new fitting function that calculates crystal field spectra and physical properties for a multi-site case.
- Added CrystalFieldMultiSite, a Python wrapper for new CrystalFieldFunction.
Full list of changes on GitHub