\(\renewcommand\AA{\unicode{x212B}}\)
Diffraction Changes
- New features in ISIS Powder which affect all instruments:
- ‘suffix’ parameter added for output filenames
- Offset files may now be specified by an absolute path. The default behaviour of assuming they live in calibration/label has been retained
- Output workspace names altered slightly to allow for easier renaming of GroupWorkspaces (see RenameWorkspace)
- Scripts no longer crash when current-normalising a workspace with no current. Instead, no normalisation or empty calibration is applied, and processing continues as normal
- It is now possible to set beam parameters (height and width) using
instrument_object.set_beam_parameters(height=123, width=456)
.
- Using grouping files with only one bank was enabled, and related errors to do with mismatched number of parameters were made more readable
- New features in ISIS Powder scripts for PEARL:
- Scripts now support creation of grouping .cal files from ceria run(s)
- Absorption corrections enabled for all samples, not just vanadium
subtract_empty_instrument
parameter added for disabling empty subtraction, useful for focusing empties
- New functionality for POLARIS in the ISIS Powder scripts. Some default parameters adjusted and output unsplined vanadium workspace by default.
- New algorithm EstimateDivergence v1 estimates the beam divergence due to finite slit size.
- New algorithm SumOverlappingTubes v1 combines a detector scan for D2B into a single workspace.
- CalculateDIFC has been extended to allow for calibration workspaces from PDCalibration.
- SaveFocusedXYE has been amended to write the metadata (e.g. temperature) value in the header, in the form of the Fullprof readable keyword.
- Improvements in ISIS Powder for HRPD:
- The prompt pulse is now masked out for the long window
- Extra TOF windows 10-50 and 180-280 now supported
- Default bin widths have been updated
- Improvements in ISIS Powder for POLARIS:
- The
mode
parameter now behaves as described in the documentation - it persists through function calls and is case insensitive
- After calling create_vanadium and focus, the output workspaces always contain the sample material if it is set using
set_sample_material
. (To view the sample material, right click the workspace and click ‘Sample Material…’)
- The
CalibrationFile
is now optional in SNSPowderReduction. In this case time focussing will use ConvertUnits and the instrument geometry. Care must be taken to supply a GroupingFile
otherwise all of the spectra will be kept separate.
- SaveGSS is relaxed to accept non-TOF point data workspaces as well.
- PDCalibration returns three more diagnostic workspaces: one for the fitted peak heights, one for the fitted peak widths, and one for observed resolution.
- LoadILLDiffraction now supports D2B files with calibrated data.
- PowderDiffILLReduction and PowderDiffILLDetEffCorr enable the basic data reduction for D20 scanning powder diffractometer at ILL.
- ApplyDetectorScanEffCorr applies the calibration file generated by PowderDiffILLDetEffCorr to detector scan workspaces.
- PowderDiffILLDetScanReduction supports D2B and D20 (when doing a detector scan) powder diffraction reduction at the ILL.
- SaveGSS has been extended to allow user to specify GSAS general header, each bank’s header and XYE decimal precision for SLOG.
- SaveVulcanGSS has been moved to a workflow algorithm and largely rewritten by using recent change in histogram and Workspace2D. It is also improved such that there is no constraint on the number of spectra and number of various binning parameters on the workspace to be saved to a GSAS file for VULCAN.
- PDLoadCharacterizations now allows for the azimuthal angles to be optionally specified in the file.
- GSAS Fitting tab was added to the GUI to allow convenient GSAS-style refinement using GSASIIRefineFitPeaks
- GSASIIRefineFitPeaks has been re-integrated with the
latest version of GSAS-II, allowing Rietveld and Pawley refinement
within Mantid.
+ Fitted peaks are now output as a Mantid workspace.
- Usability improvements in the GUI:
- The “Invalid RB number” popup window in the GUI has been replaced with a more user-friendly message.
- Improved progress reporting for Calibration and Focus.
- Enabled multi-run fitting and plotting in the Fitting tab.
- Improved unit conversions when using the peak picker.
- Fixed a bug where the engineering diffraction GUI could hang when performing a long running file search.
- New algorithm LoadWAND that will load event data for WAND² integrating out the events and correctly setting the units.
- FilterPeaks now supports filtering peaks by TOF, d-spacing, and wavelength.
- HB3A reduction interface has been enhanced. A child window is added to it for users to pre-process scans and save the processed and merged data to NeXus files in order to save time when they start to reduce and visualize the data. A record file is generated along with processed scans to record the calibration information. During data reduction, scans that have been processed in pre-processing will be loaded automatically from corresponding MD files.
- IntegratePeaksMDHKL now has option to specify background shell instead of using default background determination.
- In HB3A reduction interface, section for downloading experimental data via http server has been removed from main UI.
- IntegratePeaksMDHKL now has option to specify background shell instead of using default background determination.
- IndexPeaks now has option, CommonUBForAll, to use the current UB to index all peaks from different runs. This option does not optimize the UB for the different runs.
- FindUBUsingFFT now has options to specify number of iterations to refine UB and also resolution of the search through possible orientations. Minimum angle between a,b,c vectors reduced for large unit cells.
- FindUBUsingLatticeParameters now has option to specify number of iterations to refine UB.
- SCD Event Data Reduction interface now uses the Indexing Tolerance for Index Peaks to index the peaks for the Select Cell options in Choose Cell tab. Previously it used a constant, 0.12, for the tolerance.
- SaveLauenorm now has option to save peaks in geasc format for input into exchge and then lauescale from the laue package.
- FindPeaksMD now has an option to calculate the Goniometer rotation (around y-axis only) for a constant wavelength source.
- StatisticsOfPeaksWorkspace now can accept long or short names for the point group and reflection condition.
- A basic analysis for total scattering method
create_total_scattering_pdf
has been added to POLARIS. More information can be found on the POLARIS reference page.
- The “Test the Curve Fit widget” graphical interface has been removed, it was a test harness for developers and was not intended to be exposed during earlier releases.
Release 3.12.0