\(\renewcommand\AA{\unicode{x212B}}\)
Diffraction Changes
- New algorithm to clip peaks, providing a background estimation ClipPeaks.
- Various improvements have been made to Polaris.create_total_scattering_pdf:
- The output workspace names now include run numbers.
- Control of the output binning is no longer controlled by the parameter output_binning, instead delta_r should be used.
- The Q space workspace can be rebinned before calculating the PDF by being given an input delta_q.
- Running Polaris.create_total_scattering_pdf with debug=true will preserve the self_scattering_correction workspace.
- The Lorch filter is no longer enabled by default and must be enabled with the lorch_filter parameter.
- The LoadWAND algorithm now adds duration log to the workspace.
- The PDFFourierTransform algorithm has been updated to allow for
the algorithm to be run on a PDF to obtain a spectrum density function.
- SampleDetails.set_materials now differentiates between sample density and crystal density for converting
between pdf types.
- The CalculatePlaczekSelfScattering algorithm now accepts
The crystallographic density of the sample to correct for the powder density.
- Square beam profile of 5mm x 5mm added to the PEARL_Definition_new_lowangle instrument definition file.
- The Fourier filter on Polaris.create_total_scattering_pdf no longer produces a jagged mark at the filter limit value.
- The fourier filter on Polaris.create_total_scattering_pdf no longer produces a jagged mark at the cut off point.
- Calling IndexPeaks with default modulation vectors (0,0,0) and SaveModulationInfo=True will no longer result in segmentation fault.
- EnggEstimateFocussedBackground is a new algorithm for
estimating background of powder spectra using iterative smoothing.
- The fitting tab of Engineering Diffraction UI now functions with standard Mantid fitting capability,
but with a simplified browser.
- Loading focussed runs into the fitting tab now creates a group of table workspaces containing the
proton charge weighted average and standard deviation of select log values (set in the settings).
- TOPAS files (.abc) have replaced the .dat files generated when focusing using the GUI.
- Focusing with the GUI will now generate a CSV containing the averaged values of all numerical sample logs.
- The currently loaded calibration is now shown at the bottom of the GUI.
- The location of the saved output files from the GUI is now shown in the messages log.
- The save directory is now displayed in the status bar of the GUI.
- The Inspect Background button of the Fitting tab is now only enabled when the selected
run has had a background subtraction.
- The Engineering diffraction gui no longer goes behind the workbench window when a plot is clicked on.
- A focused run cannot be loaded with the same x unit more than once
- Calling IndexPeaks with default modulation vectors (0,0,0) and SaveModulationInfo=True will no longer result in segmentation fault.
- The CombinePeaksWorkspaces algorithm now combines the modulation
vectors present in the two workspaces, provided the total number of vectors is less than 3.
- FindGoniometerFromUB is a new algorithm for making UBs for runs at
different goniometer angles share common indexing, and determine the goniometer axis and rotation
required to match UBs to a reference.
- New instrument geometry for MaNDi instrument at SNS
- AddAbsorptionWeightedPathLengths is a new algorithm
for calculating the absorption weighted path length for each peak in a peaks workspace.
- H,K,L can now be edited in the table of a peaks workspace in workbench (now consistent with Mantid Plot)
- The peaks workspace table display now contains a column showing the value of the intensity/sigma for each peak.
- SliceViewer can now correctly display non-orthogonal axes for output of the MDNorm algorithm.
- Ellipsoid integration now supported in IntegratePeaksMD with option to fix orientation of ellipsoid to have one axis parallel to Q of peak.
Release 5.1.0