Name | Direction | Type | Default | Description |
---|---|---|---|---|
Workspace | InOut | MatrixWorkspace | Mandatory | The name of the input workspace to apply the calibration to |
CalibrationTable | Input | TableWorkspace | The name of the table workspace containing the new positions of detectors | |
PositionTable | Input | TableWorkspace | Deprecated: Use Property ‘CalibrationTable’ |
Update detector calibration from input table workspace. Current calibration properties are: - Table column Detector Position for absolute positions - Table column Detector Y Coordinate for absolute position along the vertical (Y) axis - Table column Detector Height for detector size along the vertical (Y) axis - Table column Detector Width for detector size along the horizontal (X) axis
The CalibrationTable must have the column Detector ID (integer) and one or more of the following column(s) options:
- column Detector Position of type V3Ds
- columns Detector Y Coordinate (float) and Detector Height (float)
- column Detector Width (float)
Notice: The use of property “PositionTable” has been deprecated. Use property “CalibrationTable” instead.
This algorithm is not appropriate for rectangular detectors and won’t move them.
Example - move three detectors to specified positions that would be got from calibration
Note
To run these usage examples please first download the usage data, and add these to your path. In Mantid this is done using Manage User Directories.
from mantid.kernel import V3D
# Create Workspace with instrument
# We use HRP workspace, which has detectors that are not rectangular.
ws = Load("HRP39180.RAW")
compInfo = ws.componentInfo()
detInfo = ws.detectorInfo()
spectra = [0, 3] # Spectra of detectors to be moved
# Show positions before calibration
for i in spectra:
det = ws.getDetector(i)
xyz = det.getPos()
print("Position of Detector ID=%i before ApplyCalibration: %.1f,%.1f,%.1f" % (det.getID(), xyz.X(), xyz.Y(), xyz.Z()))
index = detInfo.indexOf(det.getID()) # detectorInfo and componentInfo index
box = compInfo.shape(index).getBoundingBox().width()
scalings = compInfo.scaleFactor(index)
width, height = box[0] * scalings[0], box[1] * scalings[1]
print('Width and Height of Detector ID=%i before ApplyCalibration: %.3f %.3f' % (det.getID(), width, height))
# Create CalibrationTable - This would be done by the calibration functions
calibTable = CreateEmptyTableWorkspace(OutputWorkspace="CalibTable")
# Add required columns
calibTable.addColumn(type="int",name="Detector ID")
calibTable.addColumn(type="V3D",name="Detector Position")
calibTable.addColumn(type="double",name="Detector Y Coordinate")
calibTable.addColumn(type="double",name="Detector Height")
calibTable.addColumn(type="double",name="Detector Width")
# Populate the columns for three detectors
detIDList = [ws.getDetector(spectra[0]).getID(), ws.getDetector(spectra[1]).getID() ]
detPosList = [V3D(9.0,0.0,0.0), V3D(10.0,3.0,0.0)]
detYCoord = [0.1, 2.9]
detWidthList = [0.011, 0.009]
detHeightList = [0.043, 0.052]
for j in range(len(detIDList)):
nextRow = {'Detector ID': detIDList[j], 'Detector Position': detPosList[j], 'Detector Y Coordinate': detYCoord[j],
'Detector Width': detWidthList[j], 'Detector Height': detHeightList[j]}
calibTable.addRow ( nextRow )
# Apply Calibration to Workspace
ApplyCalibration(Workspace=ws, CalibrationTable=calibTable)
# Show positions after calibration
for i in spectra:
det = ws.getDetector(i)
xyz = det.getPos()
print("Position of Detector ID=%i after ApplyCalibration: %.1f,%.1f,%.1f" % (det.getID(), xyz.X(), xyz.Y(), xyz.Z()))
index = detInfo.indexOf(det.getID()) # detectorInfo and componentInfo index
box = compInfo.shape(index).getBoundingBox().width()
scalings = compInfo.scaleFactor(index)
width, height = box[0] * scalings[0], box[1] * scalings[1]
print('Width and Height of Detector ID=%i after ApplyCalibration: %.3f %.3f' % (det.getID(), width, height))
Output:
Position of Detector ID=1100 before ApplyCalibration: 0.0,0.1,-0.9
Width and Height of Detector ID=1100 before ApplyCalibration: 0.010 0.049
Position of Detector ID=1103 before ApplyCalibration: 0.0,0.1,-0.9
Width and Height of Detector ID=1103 before ApplyCalibration: 0.010 0.054
Position of Detector ID=1100 after ApplyCalibration: 9.0,0.1,0.0
Width and Height of Detector ID=1100 after ApplyCalibration: 0.011 0.043
Position of Detector ID=1103 after ApplyCalibration: 10.0,2.9,0.0
Width and Height of Detector ID=1103 after ApplyCalibration: 0.009 0.052