\(\renewcommand\AA{\unicode{x212B}}\)
Instrument Viewer Widget¶
Overview¶
The Mantid visualisation system allows users to view the geometry of an instrument and also select and query individual detectors. An instrument is always shown in the context of a workspace, which contains data recorded with this instrument. The detectors are colored according to the data in the corresponding spectra of the workspace. The user can select individual detectors by clicking on them and request to see the data recorded by this detector as a table or a graph. The instrument view also allows users to see close-ups of any component.
Instrument View Pane¶
The instrument view window can be obtained by right clicking on the workspace of interest and selecting Show Instrument
.
A 2D projection of the detector arrangement will be visible with each detector pixel color coded depending on the integrated number of counts in its corresponding spectrum, as in the image below.
It is possible to alter the view of the instrument by holding down either mouse button and moving (dragging) it within the window. There are other mouse and key board controls, which are listed at the bottom of the instrument view window.
The control panel of the instrument view has four tabs: Render
, Pick
, Mask
, and Instrument
.
Render Tab¶
The Render tab contains controls for managing the on-screen appearance of the instrument and collected data.
The top-most combo-box control allows the user to select the way the instrument is projected onto the screen.
The default setting is Full 3D
which gives a 3D view of the instrument in an orthogonal projection.
The other options are unwrapped views, which project the instrument onto a curved surface and unwrap it onto the view.
There is a choice between cylinders and spheres.
The unwrapped (or flat) views allow zooming by selecting a rectangular region with the mouse (left click and drag).
Right-clicking resets the zoom, which shows the entire instrument.
The next control is Axis View
, visible only in the 3D mode, which resets the view so that the instrument is fully visible and the specified axis is perpendicular to the screen.
The Display Settings
button controls the appearance of the instrument in the view.
The Use OpenGL
option toggles between two display modes of a flat view: one that uses OpenGL to render the instrument and one that doesn’t.
This option can be useful if the instrument is viewed over a slow network connection, for example.
The Save image
button allows the image to be save into a file.
The color bar axis below maps the colors of the detectors to the integrated number of counts in their spectra.
The axis also defines the minimum and maximum values, which can be edited using the text boxes below and above the color bar.
Mantid comes with a number of color map files and these can be loaded by selecting the Display Settings
-> Color Map
.
Pick Tab¶
Pick Tab is for displaying information about detectors of an instruments and data collected by them. The parameters defined for each component may be hidden if the attribute ‘visible’ is specified as false. You can also manipulate the peak markers in this tab. At the top of the tab there is a tool bar for switching between different interactive tools. The text box below the tool bar shows textual information about selected detector:
Name
ID
Index in the workspace
Cartesian coordinates of the detector (xyz) in metres
Spherical coordinates of the detector (rtp, which stands for r, theta, and phi) where the distance is in metres and the angles are in degrees
The full path of the detector in the instrument tree
Integrated counts
The units of the X vector in the underlying workspace.
Single detector selection¶
The tool allows the user to click on detectors, which will update the mini-plot to display the spectrum of the workspace
associated with the clicked detector. The user can keep curves of interest for longer by right clicking on the detector and selecting Store curve
from the context menu.
The context menu also gives the option to save the content of the mini-plot to a new workspace. There is no limit to the number of curves that can be added to the mini-plot. Curves can be removed by right-clicking on the mini-plot and selecting the line the user wishes to remove. The same menu allows for switching between linear and log scales for the Y axis.
Tube Selection¶
The tool allows the user to click a detector and have the mini-plot display the data from the immediate parent of the detector. Usually a tube or bank, depending on the instrument.
When using this tool, the user can right-click on the mini-plot to select between a sum of the counts of all detectors in the bank/tube or counts integrated over the time bins vs the detector position in the tube.
Create a Single Crystal Peak List¶
The tool allows the user to create a single crystal peak list and add a peak to it. First, select the tool and click a detector. Then
click on the peak in the mini-plot. If it is the first peak Workbench will create a PeaksWorkspace named SingleCrystalPeakTable
and add a peak to it. Peak markers will then be displayed over the instrument.
Single Crystal Peak Eraser¶
The tool can be used to remove single crystal peaks by clicking on or dragging over the peak markers. The hatched rectangle indicates the area where peaks will be erased. The rows in the PeaksWorkspace are then deleted with the markers. The size of the rectangle can be adjusted by scrolling.
Peak Comparison Tool¶
The tool can be used to calculate the reciprocal angle between two single crystal peaks. The hatched box indicates the area in which peaks will be selected. Click on a single peak marker to select it, then again on another marker. There will be a line drawn between the two peaks and the information box will show the list of peaks falling into this spectrum.
Peak Alignment Tool¶
The tool allows for the calculation of in-plane and out-of-plane angles between a user defined plane and an out-of-plane peak in Q-space. The plane must be defined first, by selecting two peaks. Clicking while they are within the hatched box will select them, and mark them with a blue circle. Subsequent peaks will be highlighted by green circles. The information box will contain the in-plane angles (phi) and out-of-plane angles (theta) for each green peak.
Selections can be cleared by right-clicking the instrument view and selecting Clear alignment plane
.
Draw Tab¶
The Draw tab contains tools for creating and editing geometrical shapes, which can be used for selecting regions of interest (ROI) or for masking or grouping detectors. The tab contains a smaller toolbar, a shape property browser, and a set of buttons to create shapes.
Masks are created by using six tools:
Ellipse
Rectangle
Ellipse Ring
Rectangle Ring
Sector
Brush: This allows for drawing of masks arbitrarily. The size of the brush can be changed by scrolling.
There is no limit on the number of shapes. The shapes can be selected and edited by selecting . Click on the shaded part of a shape and drag to move it around or move a control point to resize.
The property browser displays the parameters of the selected shape. All sizes are given in the coordinates of the unwrapped surface the shapes are drawn on. For example, for a spherical surface it will be polar and azimuth angles in radians. The shapes are “attached” to the surface and move with it when the view is zoomed or moved. can be used to zoom in and out from the render.
Using the Drawn Shapes¶
If the shapes are being used for masking or selecting regions of interest (ROIs) they can be used in two ways:
To apply the shapes to the workspace press the
Apply to Data
button. The shapes will be applied into the underlying workspace and shown in the instrument display.To see the effect of applying the changes, but without affecting the underlying workspace, click the
Apply to View
button. This will change the view you are looking at, but not the underlying data in the workspace. Changes applied in this way can be reverted usingClearAll
button.
Masks and Regions of Interest (ROI’s) can also be saved into a separate workspace or into a file, using the options in the Apply and Save
drop-down.
If the Group
option is selected, the selected detectors can be extracted or summed into a workspace using the Save
drop-down.
Bin Masking¶
When the Mask
option is selected and the integration range is reduced, only bins within the selected range will be masked instead of whole detectors.
The shapes created with the drawing tools now select the detectors for which the bins will be masked.
Clicking the Apply bin mask to view
button will use the MaskBins algorithm mask the selected bins in the data workspace.
The Apply to Data
button will apply all defined detector and bin masks using the relevant algorithms.
Instrument Tab¶
This contains a list of components and component assemblies as they are named and arranged in the Instrument Definition File. For example, in some instruments the detectors are arranged into banks, in others - a long list. Clicking on a component moves the view of the instrument to centre on that component.
Python Control¶
Many aspects of the instrument view can be controlled from Python. To use the Python interface for the Instrument Viewer, use the following code to import the necessary libraries:
from mantidqt.widgets.instrumentview.api import get_instrumentview
Then, load the Nexus data into a workspace:
ws = LoadEventNexus(Filename=nexus_path, NumberOfBins=10)
Now we are done with the necessary preparations, time to get a handle to the window itself (this will create a fresh window):
myiv = get_instrumentview(ws)
myiv.show_view()
To set the integration range (in time-of-flight), use:
myiv.set_bin_range(1, 10000)
To switch to a different tab, use:
myiv.select_tab(0) # TabIndex
# 0: Render, 1: Pick, 2: Draw, 3: Instrument
To select the projection type (surface type), use:
myiv.select_surface_type(0) # SurfaceTypeIndex
# 0: FULL3D
# 1: CYLINDRICAL_X, 2: CYLINDRICAL_Y, 3: CYLINDRICAL_Z,
# 4: SPHERICAL_X, 5: SPHERICAL_Y, 6: SPHERICAL_Z,
# 7: SideBySide
To switch to a different viewing axis, use:
myiv.set_axis("Y+") # (Z+, Z-, Y+, Y-, X+, X-)
To select the range for the data (intensity, color map legend), use:
myiv.set_auto_scaling(False) # need to turn off autoscaling before changing anything
myiv.set_color_min(1, True) # minimum value for the colorbar
myiv.set_color_max(1000, True) # maximum value for the colorbar
myiv.set_color_range(1, 1000, True) # full range of the colorbar
myiv.set_color_scale(0) # color legend scale type
# 0: Linear, 1: SymmetricLog10, 2: Power
To start the app outside MantidWorkbench
, use the following code snippet as a starting point:
import sys
from mantidqt.gui_helper import get_qapplication
from mantid.simpleapi import LoadEventNexus
from mantidqt.widgets.instrumentview.api import get_instrumentview
# check if launched within Workbench, if not return a parent QApp for this widget
# to attach to
app, within_mantid = get_qapplication()
# prepare a valid workspace from any nexus file
nexus_path = '/SNS/EQSANS/shared/sans-backend/data/new/ornl/sans/hfir/gpsans/CG2_9177.nxs.h5'
ws = LoadEventNexus(Filename=nexus_path, NumberOfBins=10)
# setup the instrument view
myiv = get_instrumentview(ws)
# to open the app
myiv.show_view()
# select tab
myiv.select_tab(0)
# select projection (surface type)
myiv.select_surface_type(0)
# select axis
myiv.set_axis("Z-")
# select the range for the data (intensity, color map legend)
myiv.set_auto_scaling(False)
myiv.set_color_min(1, True)
myiv.set_color_max(1000, True)
myiv.set_color_range(1, 1000, True)
myiv.set_color_scale(0)
# select the integration range (time of flight)
myiv.set_bin_range(1, 10000)
# if running as a standalone app, start the QApp
if not within_mantid:
myiv.reset_view()
sys.exit(app.exec_())
NOTE: If the Instrument Viewer is launched outside of Workbench on RHEL_7, the user will need to click on the viewing widget to allow it to render correctly. For other operating systems, the Instrument Viewer widget should display the instrument properly upon launching.