Runs Tab

The Runs tab is where the majority of processing takes place. You can select your user file, batch file or manually enter data sets for reduction in the data table.

Users can also control how they would like to save their processed data using the Save Options controls, which are described below.

../../_images/runs_page.png

Using the SANS GUI

All of the data required for a SANS reduction can be entered into this page. First load the appropriate user file, which is usually written by an instrument scientist and contains the settings that relate to a series of runs.

Once the settings file is loaded other pages, documented in other sections, are activated allowing settings to be viewed and edited.

There are two ways of specifying the run numbers to analyze: as single run or batch mode. In batch mode the runs are specified in a text file separated by commas as in the batch mode specification. In both cases the directory in where those run files can be found must be present in Mantid’s “Manage Directories” dialog.

In single run mode the sample run, empty can, transmission file, etc. run numbers are entered into each box.

Next click “Load Data” and an error dialog box will appear if one of the runs is incorrect or its file cannot be found. Once the data is loaded you have the choice of a 1D or 2D reduction.

Once this is complete the name of the results workspace name will be saved into the selected save directory.

Main Controls

Manage Directories

Allows a user to select the location of data and mask files

Load User File

To select the user file to load and use

Load Batch File

Selects a batch file which will pre-populate the table with run numbers

Process Selected

Processes the selected row from the table

Process All

Processes all rows in the table

Load

Loads the run data associated with the selected row from the table

Table Controls

../../_images/runs_page_table.png

Insert row after

Adds a row after the currently selected row

Delete row

Deletes the selected row

Copy selected

Creates a copy of the selected rows

Cut selected

Cuts the selected rows

Paste selected

Pastes rows from the clipboard

Clear selected

Clears the entries from selected rows without deleting them

Table Columns

SampleScatter

Scattering data file or run number to use. This is the only mandatory field

SampleTrans

Transmission data file or run number to use

SampleDirect

Direct data file or run number to use

CanScatter

Scattering datafile or run number for the can run

CanTrans

Transmission datafile or run number for can run

CanDirect

Direct datafile or run number for can run

OutputName

Name of output workspace

User File

User file to use for this row. If specified it will override any options set in the GUI, with those set in the specified user file

Sample Thickness

Sets the sample thickness to be used in the reduction

Options

This column allows the user to provide row specific settings. Currently only WavelengthMin, WavelengthMax and EventSlices can be set (see below for details)

Save Options

../../_images/runs_page_save_opts.png

Save Other

Opens up the save a dialog box Save Other which allows users to manually save processed data

Save Options - Memory

Keeps the workspaces in memory, but does not save.

Save Options - Load

Saves the workspace to the user’s output directory and removes from memory afterwards

Save Options - Both

Saves the workspace to the user’s output directory and keeps it in memory

CanSAS/NxCanSAS/RKH

Tick boxes which allow the user to select the file formats to save into

Zero Error Free

Ensures that zero error entries get artificially inflated when the data is saved This is beneficial if you wish to load the processed data into different analysis tools

Use optimizations

(Strongly Recommended) This will reuse already loaded data rather than reloading it for each run in the table, speeding up processing considerably.

Plot results

If enabled, data is automatically plotted on a graph as it is processed.