AlignComponents v1

../_images/ImageNotFound.png

Enable screenshots using DOCS_SCREENSHOTS in CMake

Summary

Align a component by minimising difference to an offset workspace

Properties

Name

Direction

Type

Default

Description

PeakCentersTofTable

Input

TableWorkspace

Mandatory

Table of found peak centers, in TOF units

PeakPositions

Input

dbl list

Comma separated list of reference peak center d-spacings, sorted by increasing value.

AdjustmentsTable

Input

string

Name of output table containing optimized locations and orientations for each component

DisplacementsTable

Input

string

Name of output table containing changes in position and euler angles for each bank component

MaskWorkspace

Input

MatrixWorkspace

Mask workspace

InstrumentFilename

Input

string

Instrument filename. Allowed extensions: [‘.xml’]

InputWorkspace

Input

Workspace

Workspace containing the instrument to be calibrated

OutputWorkspace

Output

Workspace

Mandatory

Workspace containing the calibrated instrument

FitSourcePosition

Input

boolean

False

Fit the source position, changes L1 (source to sample) distance. Uses entire instrument. Occurs before Components are Aligned.

FitSamplePosition

Input

boolean

False

Fit the sample position, changes L1 (source to sample) and L2 (sample to detector) distance.Uses entire instrument. Occurs before Components are Aligned.

ComponentList

Input

str list

Comma separated list on instrument components to refine.

Xposition

Input

boolean

False

Refine Xposition of source and/or sample and/or components

MinXposition

Input

number

-0.1

Minimum relative X bound (m)

MaxXposition

Input

number

0.1

Maximum relative X bound (m)

Yposition

Input

boolean

False

Refine Yposition of source and/or sample and/or components

MinYposition

Input

number

-0.1

Minimum relative Y bound (m)

MaxYposition

Input

number

0.1

Maximum relative Y bound (m)

Zposition

Input

boolean

False

Refine Zposition of source and/or sample and/or components

MinZposition

Input

number

-0.1

Minimum relative Z bound (m)

MaxZposition

Input

number

0.1

Maximum relative Z bound (m)

EulerConvention

Input

string

YZX

Euler angles convention used when calculating and displaying angles,eg XYZ corresponding to alpha beta gamma. Allowed values: [‘ZXZ’, ‘XYX’, ‘YZY’, ‘ZYZ’, ‘XZX’, ‘YXY’, ‘XYZ’, ‘YZX’, ‘ZXY’, ‘XZY’, ‘ZYX’, ‘YXZ’]

AlphaRotation

Input

boolean

False

Refine rotation around first axis, alpha, for the components

MinAlphaRotation

Input

number

-10

Minimum relative alpha rotation (deg)

MaxAlphaRotation

Input

number

10

Maximum relative alpha rotation (deg)

BetaRotation

Input

boolean

False

Refine rotation around seconds axis, beta, for the components

MinBetaRotation

Input

number

-10

Minimum relative beta rotation (deg)

MaxBetaRotation

Input

number

10

Maximum relative beta rotation (deg)

GammaRotation

Input

boolean

False

Refine rotation around third axis, gamma, for the components

MinGammaRotation

Input

number

-10

Minimum relative gamma rotation (deg)

MaxGammaRotation

Input

number

10

Maximum relative gamma rotation (deg)

Minimizer

Input

string

L-BFGS-B

Minimizer to Use. Allowed values: [‘L-BFGS-B’, ‘differential_evolution’]

MaxIterations

Input

long

100

Maximum number of iterations for minimizer differential_evolution

Description

This algorithm will take a table of peak-center positions (TOF units) for every pixel, and minimize the following quantity by moving and rotating instrument components.

\[\sum_i^{N_d}\sum_j^{M_i} \frac{|DIFC_i * TOF_{i,j} - d^{exp}_j|}{d^{exp}_j}\]

where the sums is for all \(N_d\) detector pixels in a given instrument component and all \(M_i\) peak centers observed at detector pixel \(i\). The quantity to be summed is the absolute value of the fractional difference between the observed peak center in d-spacing units for detector pixel \(i\) and peak \(j\), \(DIFC_i * TOF_{i,j}\), and a reference experimental value for the d-spacing of peak \(j\), \(d^{exp}_j\). The conversion from peak center in TOF units (\(TOF_{i,j}\)) to d-spacing units is carried out via the geometrical parameter \(DIFC_i\) – see AlignDetectors v1 for more information regarding this parameter. As we change the location and orientations of the instrument components during the minimization, the geometrical parameter \(DIFC_i\) is bound to change.

Below’s an example of the table of peak-center positions in TOF units for a sample having two peaks with reference peak centers of 5.1483 and 5.2070 Angstroms for an instrument consisting of one bank with four pixels:

detid

@5.1483

@7.2070

1

10000.0

nan

2

10010.0

nan

3

nan

6000.0

4

10030.0

6010.0

The first pixel contains the 5.1483A peak at \(TOF = 10000.0 \mu s\) and the 7.2070A peak is not observed. Similary for the second pixel. The third pixels observes the second peak but not the first, and the fourth pixel observes both peaks.

It is required that the reference peak centers in d-spacing have at least a precision of 5 digits.

ComponentList

The ComponentList can include any instrument component that can be moved and rotated by MoveInstrumentComponent v1 and RotateInstrumentComponent v1. For example in POWGEN you can list bank46 or Column4 (which includes banks 42-46) or Group3 (which all the banks in Column 3 and 4). In the case of a component group it is treated as one object and not individual banks. In some instruments you can also specify individual tubes or pixel, e.g. bank20/tube3 and bank20/tube3/pixel7, although that is not the intention of the algorithm. You can list multiple components which will be refined in turn (e.g. in the Align the Y rotation of bank26 and bank46 in POWGEN usage example below).

Masking

The only masking that is on taken into account when minimising the difference in DIFC is the masking in the workspace of the MaskWorkspace property of AlignComponents.

Fitting Sample/Source

When fitting the sample or source position it uses the entire instrument and moves in the directions that you select. All rotation options are ignored. You can use a masking workspace to mask part of the instrument you don’t want to use to align the sample/source position (e.g. in the Align sample position in POWGEN usage example below).

The source and sample positions (in that order) are aligned before any components are aligned.

Displacements Table

This table lists changes in position and orientation for each component other than the source and sample.

  • DeltaR: change in distance from Component to Sample (in mili-meter)

  • DeltaX: change in X-coordinate of Component (in mili-meter)

  • DeltaY: change in Y-coordinate of Component (in mili-meter)

  • DeltaZ: change in Z-coordinate of Component (in mili-meter)

Changes in Euler Angles are understood once a Euler convention is selected. If YXZ is selected, then:

  • DeltaAlpha: change in rotation around the Y-axis (in degrees)

  • DeltaBeta: change in rotation around the X-axis (in degrees)

  • DeltaGamma: change in rotation around the Z-axis (in degrees)