\(\renewcommand\AA{\unicode{x212B}}\)

LoadSampleEnvironment v1

../_images/ImageNotFound.png

Enable screenshots using DOCS_SCREENSHOTS in CMake

Summary

The algorithm loads an Environment into the instrument of a workspace at the sample.

See Also

CopySample, SetSampleMaterial, LoadSampleShape

Properties

Name

Direction

Type

Default

Description

InputWorkspace

Input

MatrixWorkspace

Mandatory

The name of the workspace containing the instrument to add the Environment

Filename

Input

string

Mandatory

The path name of the file containing the Environment. Allowed extensions: [‘.stl’, ‘.3mf’]

Scale

Input

string

cm

The scale of the stl: m, cm, or mm

OutputWorkspace

Output

MatrixWorkspace

Mandatory

The name of the workspace that will contain the loaded Environment of the sample

EnvironmentName

Input

string

Environment

Add

Input

boolean

False

XDegrees

Input

number

0

The degrees to rotate on the x axis by

YDegrees

Input

number

0

The degrees to rotate on the y axis by

ZDegrees

Input

number

0

The degrees to rotate on the z axis by

TranslationVector

Input

dbl list

0,0,0

Vector by which to translate the loaded environment

SetMaterial

Input

boolean

False

ChemicalFormula

Input

string

The chemical formula, see examples in documentation

AtomicNumber

Input

number

0

The atomic number

MassNumber

Input

number

0

Mass number if ion (use 0 for default mass sensity)

SampleNumberDensity

Input

number

Optional

This number density of the sample in number of atoms per cubic angstrom will be used instead of calculated

ZParameter

Input

number

Optional

Number of formula units in unit cell

UnitCellVolume

Input

number

Optional

Unit cell volume in Angstoms^3. Will be calculated from the OrientedLattice if not supplied.

CoherentXSection

Input

number

Optional

Optional: This coherent cross-section for the sample material in barns will be used instead of tabulated

IncoherentXSection

Input

number

Optional

Optional: This incoherent cross-section for the sample material in barns will be used instead of tabulated

AttenuationXSection

Input

number

Optional

Optional: This absorption cross-section for the sample material in barns will be used instead of tabulated

ScatteringXSection

Input

number

Optional

Optional: This total scattering cross-section (coherent + incoherent) for the sample material in barns will be used instead of tabulated

AttenuationProfile

Input

string

The path name of the file containing the attenuation profile. Allowed extensions: [‘.dat’]

SampleMassDensity

Input

number

Optional

Measured mass density in g/cubic cm of the sample to be used to calculate the number density.

NumberDensityUnit

Input

string

Atoms

Choose which units SampleNumberDensity referes to. Allowed values: [‘Atoms’, ‘Formula Units’]

Description

Loads an environment into the sample of a workspace, either replacing the current environment, or adding to it. The newly added Environment can be translated by a vector, and rotated by an angle along each axis applied in order X,Y,Z, rotation applies before translation. You may also set a material for the environment to be loaded, this follows the same inputs as SetSampleMaterial v1.

The following types of input file are supported:

  • *.stl stereolithography https://en.wikipedia.org/wiki/STL_(file_format) This is a file format consisting of a list of faces specified by their vertex coordinates. The file may be in ASCII or Binary format, and all the faces must be triangular. The normals are ignored, but the vertices must be in the order required by the standard (counter-clockwise when viewed from outside).

  • *.3mf https://3mf.io This is a 3D printing format that allows multiple objects to be stored in a single file, each with a representation similar to the .stl format ie a list of faces and vertices

Categories: AlgorithmIndex | DataHandling\Instrument

Source

C++ header: LoadSampleEnvironment.h