Filter out events from an EventWorkspace based on a sample log value satisfying filter criteria.

Properties

Name Direction Type Default Description
InputWorkspace Input EventWorkspace Mandatory An input event workspace
OutputWorkspace Output EventWorkspace Mandatory The name to use for the output workspace
LogName Input string Mandatory Name of the sample log to use to filter. For example, the pulse charge is recorded in ‘ProtonCharge’.
MinimumValue Input number Optional Minimum log value for which to keep events.
MaximumValue Input number Optional Maximum log value for which to keep events.
TimeTolerance Input number 0 Tolerance, in seconds, for the event times to keep. A good value is 1/2 your measurement interval. For a single log value at time T, all events between T+-Tolerance are kept. If there are several consecutive log values matching the filter, events between T1-Tolerance and T2+Tolerance are kept.
LogBoundary Input string Centre How to treat log values as being measured in the centre of the time, or beginning (left) boundary. Allowed values: [‘Centre’, ‘Left’]
PulseFilter Input boolean False Optional. Filter out a notch of time for each entry in the sample log named. A notch of width 2*TimeTolerance is centered at each log time. The value of the log is NOT used.This is used, for example, to filter out veto pulses.

Description

Filters out events using the entries in the Sample Logs.

Sample logs consist of a series of pairs. The first step in filtering is to generate a list of start-stop time intervals that will be kept, using those logs.

  • Each log value is compared to the min/max value filters to determine whether it is “good” or not.
    • For a single log value that satisfies the criteria at time T, all events between T+-Tolerance (LogBoundary=Centre), or T and T+Tolerance (LogBoundary=Left) are kept.
    • If there are several consecutive log values matching the filter, events between T1-Tolerance and T2+Tolerance, where T2 is the last “good” value (LogBoundary=Centre), or T1 and T2, where T2 is the first “bad” value (LogBoundary=Left) are kept.
  • The filter is then applied to all events in all spectra. Any events with pulse times outside of any “good” time ranges are removed.

There is no interpolation of log values between the discrete sample log times at this time. However, the log value is assumed to be constant at times before its first point and after its last. For example, if the first temperature measurement was at time=10 seconds and a temperature within the acceptable range, then all events between 0 and 10 seconds will be included also. If a log has a single point in time, then that log value is assumed to be constant for all time and if it falls within the range, then all events will be kept.

Warning

FilterByLogValue is not suitable for fast log filtering.

PulseFilter (e.g. for Veto Pulses)

If you select PulseFilter, then events will be filtered OUT in notches around each time in the selected sample log, and the MinValue/MaxValue parameters are ignored. For example:

  • If you have 3 entries at times:
    • 10, 20, 30 seconds.
    • A TimeTolerance of 1 second.
  • Then the events at the following times will be EXCLUDED from the output:
    • 9-11; 19-21; 29-30 seconds.

The typical use for this is to filter out “veto” pulses from a SNS event nexus file. Some of these files have a sample log called “veto_pulse_time” that only contains times of the pulses to be rejected. For example, this call will filter out veto pulses:

ws = FilterByLogValue(ws, LogName="veto_pulse_time", PulseFilter="1")

Comparing with other event filtering algorithms

The Event Filtering page has a detailed introduction on event filtering in mantid.

Usage

Example - Filtering by a simple time series Log

ws = CreateSampleWorkspace("Event",BankPixelWidth=1)

AddTimeSeriesLog(ws, Name="proton_charge", Time="2010-01-01T00:00:00", Value=100)
AddTimeSeriesLog(ws, Name="proton_charge", Time="2010-01-01T00:10:00", Value=100)
AddTimeSeriesLog(ws, Name="proton_charge", Time="2010-01-01T00:20:00", Value=100)
AddTimeSeriesLog(ws, Name="proton_charge", Time="2010-01-01T00:30:00", Value=100)
AddTimeSeriesLog(ws, Name="proton_charge", Time="2010-01-01T00:40:00", Value=15)
AddTimeSeriesLog(ws, Name="proton_charge", Time="2010-01-01T00:50:00", Value=100)

print("The unfiltered workspace {} has {} events and a peak value of {:.2f}".format(ws, ws.getNumberEvents(),ws.readY(0)[50]))

wsOut = FilterByLogValue(ws,"proton_charge",MinimumValue=75, MaximumValue=150)

print("The filtered workspace {} has {} events and a peak value of {:.2f}".format(wsOut, wsOut.getNumberEvents(),wsOut.readY(0)[50]))

Output:

The unfiltered workspace ws has 1900 events and a peak value of 2...
The filtered workspace wsOut has 950 events and a peak value of 1...

Categories: AlgorithmIndex | Events\EventFiltering

Source

C++ source: FilterByLogValue.cpp (last modified: 2019-07-17)

C++ header: FilterByLogValue.h (last modified: 2018-10-05)