\(\renewcommand\AA{\unicode{x212B}}\)
Traverse Field sinususodally modulated oscillation. Sinusoidal distribution of precession frequencies about bias e.g. from SDW.
where,
\(A_0\) is the amplitude,
\(\omega\) is the oscillation frequency,
\(phi\) is the phase,
and \(\omega_\text{mod}\) (G) is the modulation frequency.
(Source code, png, hires.png, pdf)
Name | Default | Description |
---|---|---|
A0 | 0.2 | |
Freq | 1.0 | Oscillation Frequency (MHz) |
ModFreq | 0.1 | Modulation Frequency (MHz) |
Phi | 0.0 | Phase |
[1] F.L. Pratt, Physica B 289-290, 710 (2000).
Categories: FitFunctions | Muon\MuonSpecific