\(\renewcommand\AA{\unicode{x212B}}\)

EQSANSDirectBeamTransmission v1

../_images/EQSANSDirectBeamTransmission-v1_dlg.png

EQSANSDirectBeamTransmission dialog.

Table of Contents

Summary

Compute the transmission using the direct beam method on EQSANS

Properties

Name Direction Type Default Description
InputWorkspace Input MatrixWorkspace Mandatory  
SampleDataFilename Input string Mandatory Allowed values: [‘xml’, ‘nxs’, ‘nxs.h5’]
EmptyDataFilename Input string Mandatory Allowed values: [‘xml’, ‘nxs’, ‘nxs.h5’]
BeamRadius Input number 3 Beam radius [pixels]
ThetaDependent Input boolean True If true, a theta-dependent correction will be applied
DarkCurrentFilename Input string   Allowed values: [‘xml’, ‘nxs’, ‘nxs.h5’]
UseSampleDarkCurrent Input boolean True If true, the sample dark current will be used
BeamCenterX Input number 0 Beam center position in X
BeamCenterY Input number 0 Beam center position in Y
FitFramesTogether Input boolean False If true, the two frames will be fit together
ReductionProperties Input string __sans_reduction_properties Property manager name for the reduction
OutputWorkspace Output MatrixWorkspace Mandatory Workspace containing the data corrected for the transmission.
TransmissionWorkspace Output MatrixWorkspace   Workspace containing the fitted transmission distribution.
RawTransmissionWorkspace Output MatrixWorkspace   Workspace containing the transmission distribution before fitting.
OutputMessage Output string   Output message

Description

Compute the transmission using the direct beam method on EQSANS

Categories: AlgorithmIndex | Workflow\SANS\UsesPropertyManager