\(\renewcommand\AA{\unicode{x212B}}\)
Muon Changes
- Users can now select the unit for the frequency spectra (MHz or Gauss) in plotting, by picking either
Frequency
or Field
respectively after a transform has been calculated.
- Fixed a bug that prevented the frequency spectra from being plotted when data was binned.
- When plotting transformations, FFTs now have y-units of
intensity
and Maxents now have y-units of probability
.
- Instead of plotting the confidence interval of a fit as an error bar, it is now represented by a shaded region.
- Changes have been made to improve the speed of Muon Analysis and Frequency Domain Analysis.
- The Results Tab will now display a warning (red text and a tooltip) if the results table already exists.
- The results table now produces errors for log values (when they are available).
- The plots no longer use scientific notation for the axis values.
- On resizing the GUI, priority is given to plotting.
- The plot guess option in Fitting can now have its range interpolated or extrapolated.
- The
alpha
values on Grouping Tab are now to six decimal places.
- The numerical values in the
run info
box on the Home Tab are now rounded to either 4 significant figures or a whole number, whichever is more precise.
- The Sequentially Fit all button is now visible for 4K displays.
- The Results Tab will now preserve the workspace selection after a fit. However, it will reselect a fit that has been recalculated.
- When using
Browse
to load data from a different instrument, a warning is now shown saying that the data has not been loaded.
- Detaching tabs in Muon Analysis or Frequency Domain Analysis GUIs and then closing Mantid no longer causes a crash.
- Dragging tabs in Muon Analysis or Frequency Domain Analysis GUIs no longer shows a translucent preview that does nothing.
- Mantid no longer crashes when changing tabs in either Muon Analysis or Frequency Domain Analysis on MacOS.
- Fixed a bug that prevented the GUI working with workspace history and project recovery.
- Undo fit now resets when the function structure changes. This prevents a bug caused by trying to revert the current function to the state of a previous one.
- When a new fit is performed in Muon Analysis or Frequency Domain Analysis it no longer reselects all parameter workspaces in the results tab.
- Can now read
nxs_v2
files.
- Fixed a bug that allowed decimal values for custom groupings.
- Added two Activation fitting functions to
MuonModelling
Fit Functions.
- Added a Critical peak of relaxation rate for fitting to
MuonModelling\Magnetism
Fit Functions.
- Added two fitting functions for the decoupling of asymmetry in the ordered state of a powedered magnet for fitting.
- Added a Magentic Order Parameter function to
MuonModelling\Magentism
Fit Functions.
- Added a Muonium-style Decoupling Curve function to
MuonModelling
Fit Functions.
- Added a Power Law fitting function to
MuonModelling
Fit Functions.
- Added a Smooth Transition function to
MuonModelling
Fit Functions.