\(\renewcommand\AA{\unicode{x212B}}\)

Diffraction Changes

Powder Diffraction

New features

  • New algorithm to clip peaks, providing a background estimation ClipPeaks.

Improvements

  • Various improvements have been made to Polaris.create_total_scattering_pdf: - The output workspace names now include run numbers. - Control of the output binning is no longer controlled by the parameter output_binning, instead delta_r should be used. - The Q space workspace can be rebinned before calculating the PDF by being given an input delta_q. - Running Polaris.create_total_scattering_pdf with debug=true will preserve the self_scattering_correction workspace. - The Lorch filter is no longer enabled by default and must be enabled with the lorch_filter parameter.

  • The LoadWAND algorithm now adds duration log to the workspace.

  • The PDFFourierTransform algorithm has been updated to allow for the algorithm to be run on a PDF to obtain a spectrum density function.

  • SampleDetails.set_materials now differentiates between sample density and crystal density for converting between pdf types.

  • The CalculatePlaczekSelfScattering algorithm now accepts The crystallographic density of the sample to correct for the powder density.

  • Square beam profile of 5mm x 5mm added to the PEARL_Definition_new_lowangle instrument definition file.

Bugfixes

  • The Fourier filter on Polaris.create_total_scattering_pdf no longer produces a jagged mark at the filter limit value.

  • The fourier filter on Polaris.create_total_scattering_pdf no longer produces a jagged mark at the cut off point.

  • Calling IndexPeaks with default modulation vectors (0,0,0) and SaveModulationInfo=True will no longer result in segmentation fault.

Engineering Diffraction

../../_images/EnggDiff_5_1_0.png

New features

  • EnggEstimateFocussedBackground is a new algorithm for estimating background of powder spectra using iterative smoothing.

  • The fitting tab of Engineering Diffraction UI now functions with standard Mantid fitting capability, but with a simplified browser.

  • Loading focussed runs into the fitting tab now creates a group of table workspaces containing the proton charge weighted average and standard deviation of select log values (set in the settings).

Improvements

  • TOPAS files (.abc) have replaced the .dat files generated when focusing using the GUI.

  • Focusing with the GUI will now generate a CSV containing the averaged values of all numerical sample logs.

  • The currently loaded calibration is now shown at the bottom of the GUI.

  • The location of the saved output files from the GUI is now shown in the messages log.

  • The save directory is now displayed in the status bar of the GUI.

  • The Inspect Background button of the Fitting tab is now only enabled when the selected run has had a background subtraction.

Bugfixes

  • The Engineering diffraction gui no longer goes behind the workbench window when a plot is clicked on.

  • A focused run cannot be loaded with the same x unit more than once

  • Calling IndexPeaks with default modulation vectors (0,0,0) and SaveModulationInfo=True will no longer result in segmentation fault.

Single Crystal Diffraction

Improvements

  • The CombinePeaksWorkspaces algorithm now combines the modulation vectors present in the two workspaces, provided the total number of vectors is less than 3.

  • FindGoniometerFromUB is a new algorithm for making UBs for runs at different goniometer angles share common indexing, and determine the goniometer axis and rotation required to match UBs to a reference.

  • New instrument geometry for MaNDi instrument at SNS

  • AddAbsorptionWeightedPathLengths is a new algorithm for calculating the absorption weighted path length for each peak in a peaks workspace.

  • H,K,L can now be edited in the table of a peaks workspace in workbench (now consistent with Mantid Plot)

  • The peaks workspace table display now contains a column showing the value of the intensity/sigma for each peak.

  • SliceViewer can now correctly display non-orthogonal axes for output of the MDNorm algorithm.

  • Ellipsoid integration now supported in IntegratePeaksMD with option to fix orientation of ellipsoid to have one axis parallel to Q of peak.

Release 5.1.0