\(\renewcommand\AA{\unicode{x212B}}\)

Direct Geometry Changes

General

New features

  • SaveNXSPE now stores the run number of the input workspace in the instrument section.

    For Indirect instruments it also saves efixed, taken from the detector’s crystal analyzer properties. If all crystal analyzers have the same energy, a single efixed is written into NXSPE_info->fixed_energy as before, while if detectors have different analyzer energies, an array of the energies is written into the NXSPE_info->fixed_energy field of the .nxspe file. Also for Indirect instruments, no fermi field is added to the instrument folder. The algorithm has also been modified so if Ei is provided as the propery value it always overrides the values retrieved from the workspace.

Bugfixes

  • ALFView no longer crashs when moving the cursor over the Instrument View while loading data.

  • ALFView no longer crashes when closing the interface while it is loading data.

  • PyChop no longer uses random phase values on Merlin when instrument scientist mode disabled.

  • Fix for incorrect incident energies for MERLIN in PyChop when not in instrument scientist mode.

MSlice

New features

  • None is now a new line style option. With this feature, it is possible to plot error bars without including a line.

  • The spectrum ID is no longer printed when saving a 2D workspace as an ASCII file.

Bugfixes

  • The Intensity menu on slice plots is now disabled in interactive mode to prevent crashes.

  • Bug fix implemented to save cut data in a 3-column file instead of a single line.

CrystalField

Bugfixes

  • The method cf.getMagneticMoment() no longer ignores the Hmag field, which is now correctly considered in the calculations of the magnetic moment.

Release 6.11.0